Fault Code 33
Synopsis
Description: Air conditioning
cut-out relay circuit is open or shorted
Power loss light: Off
Limp-in mode: None
Possible Causes
Bad connection or wiring - Check the wiring and connections between
the logic module and the relay. Clean and regrease any corroded connectors
with dielectric grease and repair any shorts.
Bad relay - Disconnect the relay and apply 12V across the coil
terminals (dark blue wire on single connector and dark blue with orange
stripe on 3-terminal connector). You should hear a click and the
connection between the other two terminals should be shorted.
Diagnostic Method
Trigger Parameters
- Near 0V or near 12V not detected when the relay is turned on or off,
respectively
Results If Component Fails
Fault code 33 is stored.
This page is maintained by Russell W. Knize and was last updated 08/28/98.
Comments? Questions? Send email.