Fault Code 33

Synopsis

Description:  Air conditioning cut-out relay circuit is open or shorted
Power loss light:  Off
Limp-in mode:  None
 

Possible Causes

Bad connection or wiring - Check the wiring and connections between the logic module and the relay.  Clean and regrease any corroded connectors with dielectric grease and repair any shorts.

Bad relay - Disconnect the relay and apply 12V across the coil terminals (dark blue wire on single connector and dark blue with orange stripe on 3-terminal connector).  You should hear a click and the connection between the other two terminals should be shorted.
 

Diagnostic Method

Trigger Parameters

- Near 0V or near 12V not detected when the relay is turned on or off, respectively

Results If Component Fails

Fault code 33 is stored.
 
 
 
Return to the Fault Codes Page

 
 